Continuous audio sampling

When you are classifying audio - for example to detect keywords - you want to make sure that every piece of information is both captured and analyzed, to avoid missing events. This means that your device need to capture audio samples and analyze them at the same time. In this tutorial you'll learn how to continuously capture audio data, and then use the continuous inferencing mode in the Edge Impulse SDK to classify the data.

This tutorial assumes that you've completed the Recognize sounds from audio tutorial, and have your impulse running on your device.

Continuous inference mode

Continuous inferencing is automatically enabled for any impulses that use audio on both the ST B-L475E-IOT01A and the Arduino Nano 33 BLE Sense development boards. Build and flash a ready-to-go binary for your development board from the Deployment tab in the studio, then - from a command prompt or terminal window - run edge-impulse-run-impulse --continuous.

An Arduino sketch that demonstrates continuous audio sampling is part of the Arduino library deployment option. After importing the library into the Arduino IDE, look under 'Examples' for 'nano_ble33_sense_audio_continuous'.

Continuous Inferencing

In the normal (non-continuous) inference mode when classifying data you sample data until you have a full window of data (e.g. 1 second for a keyword spotting model, see the Create impulse tab in the studio), you then classify this window (using the run_classifier function), and a prediction is returned. Then you empty the buffer, sample new data, and run the inferencing again. Naturally this has some caveats when deploying your model in the real world: 1) you have a delay between windows, as classifying the window takes some time and you're not sampling then, making it possible to miss events. 2) there's no overlap between windows, thus if an event is at the very end of the window, not the full event might be captured - leading to a wrong classification.

To mitigate this we have added a number of new features to the Edge Impulse SDK.

1. Model slices

Using continuous inferencing, smaller sampling buffers (slices) are used and passed to the inferencing process. In the inferencing process the buffers are time sequentially placed in a FIFO (First In First Out) buffer that matches the model size. After each iteration, the oldest slice is removed at the end of the buffer and a new slice is inserted at the beginning. On each slice now, inference is run multiple times (depending on the number of slices used for a model). For example, a 1 second keyword model with 4 slices (each 250 ms), will inference each slice 4 times. So if now the keyword is on 2 edges of the slice buffers, they're glued back together in the FIFO buffer and the keyword will be classified correctly.

2. Averaging

Another advantage of this technique is that it filters out false positives. Take for instance a yes-no keyword spotting model. The word 'yesterday' should not be classified as a yes (or no). But if the 'yes-' is sampled in the first buffer and '-terday' in the next, there is a big chance that the inference step will classify the first buffer as a yes.

By running inference multiple times over the slices, continuous inferencing will filter out this false positive. When the 'yes' buffer enters the FIFO it will surely classify a 'yes'. But as the rest of the word enters, the classified value for 'yes' will drop quickly. We just have to make sure that we don't react on peak values. Therefor a moving average filter averages the classified output and so flattens the peaks. To have a valid 'yes', we now need multiple high rated classifications.

Continuous audio sampling

In the standard way of running the impulse, the steps of collecting data and running the inference are run sequential. First the audio is sampled, filling a block the size of the model. This block is send to the inferencing part, where first the features are extracted and then inference is run. Finally the classified output is used in your application (by default the output will be printed over de serial connection).

In the continuous sampling method, audio is sampled in parallel with the inferencing and output steps. So while inference is running, audio sampling continues on a background process.

Implementing continuous audio sampling

We've implemented continuous audio sampling already on the ST B-L475E-IOT01A and the Arduino Nano 33 BLE Sense targets (the firmware for both targets is open source), but here's a guideline to implementing this on your own targets.

Prerequisites

The embedded target needs to support running of multiple processes in parallel. This can either be achieved by an operating system; 1 low priority thread will run inferencing and 1 high priority thread will collect sample data. Or the processor should support processor offloading. This is usually done by the audio peripheral or DMA (Direct Memory Access). Here audio samples are collected in a buffer without involvement of the processor.

Double buffering

How do we know when new sample data is available? For this we use a double buffering mechanism. Hereby 2 sample buffers are used:

  • 1 buffer for the audio sampling process, filling the buffer with new sample data

  • 1 buffer for the inference process, get sample data out the buffer, extract the features and run inference

At start, the sampling process starts filling a buffer with audio samples. Meanwhile, the inference process waits until the buffer is full. When that happens, the sampling process passes the buffer to the inference process and starts sampling on the second buffer. Each iteration, the buffers will be switched so that there is always an empty buffer for sampling and a full buffer of samples for inferencing.

Timing and memory is everything

There are 2 constraints in this story: timing and memory. When switching the buffers there must be a 100% guarantee that the inference process is finished when the sampling process passes a full buffer. If not, the sampling process overruns the buffer and sampled data will get lost. When that happens on the ST B-L475E-IOT01A or the Arduino Nano 33 BLE Sense target, running the impulse is aborted and the following error is returned:

Error sample buffer overrun. Decrease the number of slices per model window (EI_CLASSIFIER_SLICES_PER_MODEL_WINDOW)

The EI_CLASSIFIER_SLICES_PER_MODEL_WINDOW macro is used to set the number of slices to fill the complete model window. The more slices per model, the smaller the slice size, thereby the more inference cycles on the sampled data. Leading to more accurate results. The sampling process uses this macro for the buffer size. Where following rule applies: the bigger the buffer, the longer the sampling cycle. So on targets with lower processing capabilities, we can increase this macro to meet the timing constraint.

Increasing the slice size, increases the volatile memory uses times 2 (since we use double buffering). On a target with limited volatile memory this could be a problem. In this case you want the slice size to be small.

Double buffering in action

On both the ST B-L475E-IOT01A and Arduino Nano 33 BLE Sense targets the audio sampling process calls the audio_buffer_inference_callback() function when there is data. Here the number of samples (inference.n_samples) are stored in one of the buffers. When the buffer is full, the buffers are switched by toggling inference.buf_select. The inference process is signaled by setting the flag inference.buf_ready.

static void audio_buffer_inference_callback(uint32_t n_bytes, uint32_t offset)
{
    for (uint32_t i = 0; i< (n_bytes >>  1); i++) {
        inference.buffers[inference.buf_select][inference.buf_count++] = sampleBuffer[offset + i];

        if (inference.buf_count >= inference.n_samples) {
            inference.buf_select ^= 1;
            inference.buf_count = 0;
            inference.buf_ready = 1;
        }
    }
}

The inferencing process then sets the callback function on the signal_t structure to reference the selected buffer:

int ei_microphone_audio_signal_get_data(size_t offset, size_t length, float *out_ptr)
{
    numpy::int16_to_float(&inference.buffers[inference.buf_select ^ 1][offset], out_ptr, length);
    return 0;
}

Then run_classifier_continuous() is called which will take the slice of data, run the DSP pipeline over the data, stitch data together, and then classify the data.

Last updated

Revision created

Update firmware coordinates