with Zephyr on Golioth
Introduction
This page is part of the Lifecycle Management with Edge Impulse tutorial series. If you haven't read the introduction yet, we recommend you to do so here.
In this tutorial, we'll guide you through deploying updated impulses over-the-air (OTA) using the Zephyr RTOS. We'll build on Zephyr's firmware update workflow, incorporating API calls to check for updates to your edge impulse project and download the latest build. As Zephyr does not have an OTA update service, and Golioth is used in their OTA guide. We'll use Golioth's OTA update service to deliver the updated firmware to the device. On devices running Zephyr RTOS, leveraging Golioth's cloud platform for the firmware update portion of the process.
Key Features of Golioth OTA Updates:
Secure and encrypted firmware delivery
Delta updates to minimize download size
Integration with Zephyr RTOS
Prerequisites
Edge Impulse Account: If you haven't got one, sign up here.
Trained Impulse: If you're new, follow one of our end-to-end tutorials
Knowledge of Zephyr RTOS and nRF Connect SDK
A Golioth account and the Golioth SDK installed
Preparation
Clone the Golioth Zephyr SDK examples repository:
On Your nRF9160 Development Board:
Navigate to the Golioth firmware examples folder we are going to modify the device firmware update example to connect to the ingestion API to send data back from device.
Now copy the edge-impulse-sdk folder from the cloned repository into the dfu folder.
Include the header file the dfu example
Take the run inference example from your existing project
You will need to merge in the run inference function from your existing project. This will be the function that will be called to run inference on the device.
Add the run inference function to the main loop
Now add the run inference function to the main loop of the dfu example. This will run inference every 2 seconds.
Add a call back to send sensor data to Edge Impulse with data captured
Add the send data to Edge Impulse function
Add the sensor trigger to the main function
Building and Running
With the classification, ingestion code and Golioth implementation in place, proceed to build and run the application on the nRF9160 Development Board. Utilize the following commands:
These commands will build and flash the firmware onto your development board.
Verifying The Operation
To verify that the Edge Impulse model is running and updating OTA with Golioth, observe the console output. It should display inference results at regular intervals. Also, you can monitor the device’s firmware version and its updates via the Golioth console.
Testing OTA Updates
Simulate an OTA update by changing the Edge Impulse model and repeating the build and flash process. Monitor the Golioth console for updates and check the device console to observe the changes in inference results.
Conclusion
Congratulations! You've successfully implemented OTA model updates with Edge Impulse on Zephyr RTOS and nRF Connect SDK, facilitated by Golioth. You can now continuously enhance and deploy machine learning models to your edge devices securely and efficiently.